logo
Home > Products >
Prefab Cleanroom
>
Modular , Durable Medical Device Clean Room for Pharmaceutical Manufacturing GCC Middle East

Modular , Durable Medical Device Clean Room for Pharmaceutical Manufacturing GCC Middle East

Product Details:
Place of Origin: Guangdong,China
Brand Name: GCC
Certification: ISO/GMP/CE
Detail Information
Place of Origin:
Guangdong,China
Brand Name:
GCC
Certification:
ISO/GMP/CE
Keyword:
Prefab Cleanroom
Frame Material:
Aluminum Profile, Stainless Steel Profile, Steel Profile
Wall Material:
Magnesium Sandwich Panel
Video Outgoing-inspectionv:
Provided
Machinery Test Report:
Provided
After-sales Service Provided:
Online Support
Highlight:

High Light

Highlight:

GMP Standard Medical Device Clean Room

,

GMP clean room class for medical devices

,

ISO8 Medical Device Clean Room

Trading Information
Minimum Order Quantity:
1
Price:
Negotiation
Packaging Details:
Wooden Box
Delivery Time:
14Days
Payment Terms:
T/T
Supply Ability:
5000Sets/Month
Product Description

GMP medical device cleanroom is a special designed room to exclude the particles in the air, bacteria and other harmful air pollutants, and the indoor temperature, cleanliness, interior pressure, air velocity and air distribution, noise, vibration, and lighting, static control within the scope of a certain demand. That is no matter how the outside air conditions change, its indoor all can maintain the original set requirements of cleanliness, temperature and humidity and pressure performance characteristic.

Consider Features

  1. Temperature and Relative Humidity

    Except for certain special circumstances, the temperature of medical instrument cleanrooms should be calibrated between 18~28°C, with a relatively humidity of 45-65%. If you find that you are out of range for these standards, consider which instruments in the clean room may be acting as a heat source.

  2. Air Velocity, Air Change Rate (ACR), and Static Pressure

    The air change rate of a cleanroom is a function of the volume of air circulated into the cleanroom and the area of the cleanroom. Differences in static pressure result from differences in the the amount of air circulating through the air return vs. exhaust system vents. All of these variables can be adjusted through manipulation of fan speed and/or opening/closing the main vents. These can be adjusted for the entire system or for certain areas depending on the situation.

  3. Keeping Out Dust, Bacteria, and Other Contaminants

    Indications that your clean room may not be up to standard include falling out of standard in basic areas such as temperature, relative humidity and ACR. If these variables are out of standard, it is likely that your cleanroom is contaminated to a degree that is out of standard.

    Proper calibration of the above conditions forms a sort of "microclimate" that is inhospitable to contaminants such as dust particles and bacteria. Meeting standards is a result of proper maintenance of the cleanroom. Regular, thorough testing is the only best practice, especially in a field where product contamination can lead to serious consequences. Besides designing your cleanroom, E-Clean can advise on how to implement management systems to maintain your cleanroom and minimize the risk for contamination.

Level Of Airborne Particulate Cleanliness In Prefab Cleanroom

LevelMaximum Particles/m3Equivalent
≥0.1 μm≥0.2 μm≥0.3 μm≥0.5 μm≥1 μm≥5 μm
ISO 110bdddde
ISO 210024b10bdde
ISO 3100023710235bdeClass 1
ISO 4100002370102035283beClass 10
ISO 510000023700102003520832d,e,fClass 100
ISO 61000000237000102000352008320293Class 1,000
ISO 7ccc352000832002930Class 10,000
ISO 8ccc352000083200029300Class 100,000
ISO 9ccc352000008320000293000Room Air
Area15㎡30㎡50㎡100㎡
MaterialAluminum frame/Baking steel plate/lnsulating glass window
FFU class 1-10012pcs24pcs48pcs96pcs
FFU class-1K3pcs6pcs9pcs18pcs
FFU class-10K2pcs4pcs6pcs12pcs
Speed (m/s)0.45m/s ±20%0.45m/s ±20%
Temperature (optional)18-28°C
Humidity (opiional)50-70%50-70%
Illumination400-800LUX
Power2.4-7kw4.8-10kw9.6-19kw19.2-30kw

Our Advantage

We focus on all kinds of solutions for prefab cleanroom. If you are unsure of what tpye of prefab cleanroom you may need for your particular project, please feel free to contact us. We will provide a best solution according to your requirement.

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

J
Jake
Indonesia Jan 4.2026
The pass box performs reliably during material transfer in food cleanroom environments, effectively controlling contamination risks between areas of different cleanliness classes. Its easy-to-clean structure and food-grade materials comply with HACCP and GMP requirements, providing a reliable safeguard for food safety production.
J
joy
United States Dec 24.2025
We have used the FFU in our project, and the performance is excellent! It is energy-efficient, low-noise, and delivers uniform airflow, making it an essential unit for high-standard clean production lines.
A
A*y
Nigeria Dec 2.2025
The grossing station features a well-designed downdraft exhaust system with uniform airflow. It effectively controls formalin fumes, even during long operating hours, significantly improving laboratory safety.