| Place of Origin: | Guangdong,China |
| Brand Name: | GCC |
| Certification: | ISO/GMP/CE |
| Model Number: | GCC-FFU-1200 |
| Document: | GCC-FFU-1200-Cleanroom-Layo...ut.pdf |
Our Fan Filter Unit (FFU) is engineered to provide stable, uniform airflow for cleanroom environments with strict contamination control requirements. With stepless speed control, low vibration, and ultra-low noise operation, it delivers reliable performance while minimizing maintenance over long-term use.
Each FFU is individually tested prior to shipment in accordance with ISO 14644-1, using particle counters to verify filtration efficiency and airflow consistency. The system supports centralized control of multiple units, making it ideal for large-scale cleanroom installations while reducing failure rates and operating costs.
Designed for high energy efficiency and low heat output, this FFU helps maintain stable temperature and cleanliness conditions. It is well suited for ultra-clean production lines, Class 100 (ISO 5) assembly areas, and modular cleanroom systems.
| Model | Module Size (W*L*H mm) | Air Volume (m³/h) | Average Air Velocity (m/s) | Power (W) | Filter Efficiency |
|---|---|---|---|---|---|
| GCC-FFU-500 | 575*575*230 | 500 | 0.3–0.5 | 120 | 99.99% @ 0.3μm |
| GCC-FFU-600 | 615*615*230 | 600 | 0.3–0.5 | 120 | 99.99% @ 0.3μm |
| GCC-FFU-900 | 920*615*230 | 900 | 0.3–0.5 | 200 | 99.99% @ 0.3μm |
| GCC-FFU-1000 | 1175*575*230 | 1000 | 0.3–0.5 | 120 | 99.99% @ 0.3μm |
| GCC-FFU-1200 | 1225*615*230 | 1200 | 0.3–0.5 | 200 | 99.99% @ 0.3μm |
| GCC-FFU-2000 | 1175*1175*260 | 2000 | 0.3–0.5 | 230 | 99.99% @ 0.3μm |
Note: Non-standard sizes and specifications are available upon request.
Q1: Can FFUs be centrally controlled?
Yes. Multiple FFUs can be connected to a centralized control system for unified airflow management and reduced failure rates.
Q2: What standards are the FFUs tested to?
Each unit is individually tested according to ISO 14644-1 standards before shipment.
Q3: Can you provide custom sizes or materials?
Yes. We offer non-standard dimensions, airflow ratings, and housing materials based on project requirements.
Q4: Is the FFU suitable for Class 100 cleanrooms?
Absolutely. FFUs can be arranged in series to form Class 100 (ISO 5) ultra-clean production lines.
Q5: What is the power supply requirement?
Standard power supply is 220V / 50Hz. Other options are available upon request.
Overall Rating
Rating Snapshot
The following is the distribution of all ratingsAll Reviews