Overview
The Laminar Flow Air Supply Ceiling is an essential purification device for modern hospital operating rooms and other high-cleanliness environments. Leveraging advanced leakage barrier technology, it ensures even air distribution, maintains Class 100 cleanliness, and effectively controls microbial and particulate contamination. This system is widely used in hospital operating rooms, sterile wards, clean animal rooms, pharmaceutical facilities, and laboratories.
1. High-Efficiency Purification
Equipped with 99.99% @ 0.3μm HEPA filter.
Meets Class 100 cleanliness standards, effectively controlling microbial and particulate contamination.
2. Stable Airflow Distribution
Laminar airflow design with wind speed ≥25–30 m/s.
Ensures uniform coverage over the work area, minimizing turbulence and maintaining sterility.
3. Low Noise & Energy Saving
Optimized fan system operates at <62 dB.
Supports 110V/220V/380V, 50Hz/60Hz power supply options.
4. Intelligent Control
Adjustable air shower time from 0–9 seconds for different cleanliness scenarios.
User-friendly controls for precise airflow management.
5. Durable Construction
Full stainless steel structure, corrosion-resistant and easy to clean.
Suitable for high-humidity and high-cleanliness environments.
6. Customizable Solutions
Supports custom sizes, air volumes, and filtration grades to fit diverse cleanroom requirements.
| Item | Specification |
|---|---|
| Material | Stainless Steel |
| Internal Size (mm) | 2600*2400 / 2600*1800 |
| External Size (mm) | 1200*1000*2050 |
| Filtration Efficiency | 99.99%@0.3μm, G3 |
| Voltage & Power | 110V/220V/380V, 50Hz/60Hz |
| Air Volume (m³/h) | 1200 |
| Fan Rotation Speed | 2800 RPM |
| Wind Speed (m/s) | ≥25-30 |
| Showering Time (s) | 0-9 (adjustable) |
| Noise (dB) | <62 |
| Remark | Customizable |
Q1: What applications is the laminar flow air supply ceiling suitable for?
A1: Primarily used in hospital operating rooms, sterile laboratories, pharmaceutical production facilities, electronics cleanrooms, and biosafety labs, or any environment requiring stringent air cleanliness standards.
Q2: How to maintain and replace the filters?
A2:
Primary filter (G3): Inspect, clean, or replace every 3–6 months.
HEPA filter: Service life of 1–2 years; monitor pressure differentials and replace when necessary.
Features quick-release mechanisms for easy maintenance without interrupting operations.
Q3: Can it be adapted to cleanrooms of different sizes?
A3: Yes, the system supports custom non-standard sizes. The ceiling’s length, width, and height can be adjusted for your cleanroom, with airflow optimization to ensure uniform distribution.