Chemical Fume Hood Cold Rolled Steel Perchloric Acid Handling For Pharmaceutical Chemical Research Laboratories

Chemical Fume Hood Cold Rolled Steel Perchloric Acid Handling For Pharmaceutical Chemical Research Laboratories

Product Details:
Place of Origin: Guangdong,China
Brand Name: GCC
Certification: ISO/GMP/CE
Model Number: Fume Hood
Detail Information
Place of Origin:
Guangdong,China
Brand Name:
GCC
Certification:
ISO/GMP/CE
Model Number:
Fume Hood
Keyword:
Fume Hood
Material:
Polypropylene/ Metal / Stainless Steel
Application:
Laboratory, Pharmaceutical GMP Laboratory, Sample Ratio And Weigh
Voltage:
220V/50HZ
Usage:
Perchloric Acid
Advantage:
Perchloric Acid Hoods
Filters Tyep:
Several Types Fo Carbon Filters Can Be Chosen
Feature:
Stable Quality
Function:
Remove Hazardous Fumes, Vapors And Particles
Filter:
Organic Gases, Inorganic Gases, Formaldehyde, Ammonia
Highlight:

High Light

Highlight:

Safety Perchloric Acid Fume Hood

,

Chemical Perchloric Acid Fume Hood

Trading Information
Minimum Order Quantity:
1
Price:
USD 3000/set
Packaging Details:
Wooden Box
Delivery Time:
14Days
Payment Terms:
T/T
Supply Ability:
5000Sets/Month
Product Description

This product is a high-performance specialized fume hood designed specifically for experiments involving perchloric acid and other highly corrosive chemicals. Its core design strictly adheres to chemical safety standards, constructed entirely of high-quality PVC (polyvinyl chloride) material and equipped with a built-in washdown system. This system effectively prevents the accumulation of perchlorate salt crystals, fundamentally eliminating the risk of explosion or fire caused by residual salts coming into contact with organic materials, thereby providing the highest level of safety for laboratory personnel and equipment.GCC Fume Hood

Core Advantages
  • Exceptional Corrosion Resistance: The hood body, lining, and ductwork are made of high-quality PVC material, which is entirely inert to perchloric acid, its vapors, and by-products, ensuring structural integrity and safety over long-term use.

  • Built-in Washdown System: Standard equipped with an integrated automatic/manual cleaning device that thoroughly rinses the inner walls, work surface, and exhaust duct after each experiment, preventing perchlorate salt residue and enabling proactive safety protection.

  • Integrated Drainage Design: Features a seamless drainage trough to ensure rapid and complete discharge of wash water, facilitating easy cleaning and maintenance while keeping the work area dry and tidy.

  • Stable and Reliable Quality: Strict control over materials and craftsmanship ensures consistent performance and durability in long-term, highly corrosive environments.

Key Features
  • Proactive Safety Protection: The washdown system is a critical design feature for preventing perchlorate-related accidents.

  • High Durability: PVC structure resists corrosion, ensuring a long service life.

  • Easy Maintenance: Smooth PVC surfaces and an efficient drainage system make cleaning quick and straightforward.

  • Professional Compliance: Specifically designed for handling special chemicals like perchloric acid, meeting stringent laboratory safety standards.

Parameters
Parameter Category Detailed Specifications
Main Structure Material High-quality Polyvinyl Chloride (PVC), providing comprehensive corrosion protection for all contact components.
Work Surface Integrated PVC work surface, seamlessly connected to the hood body, with a sloped design and built-in drainage trough.
Core Safety System Integrated washdown/spray system, including corrosion-resistant nozzles and water supply lines, covering the hood interior and exhaust duct entry area.
Sash Explosion-resistant transparent sash (typically made of polycarbonate or laminated glass), balanced lifting mechanism, with safe positioning.
Airflow Control Adjustable air intake baffle on the front operating face ensures uniform and stable face velocity.
Face Velocity Typically recommended operating face velocity is 0.5 m/s (±0.1 m/s), adjustable as needed.
Lighting System Sealed explosion-proof LED lighting, providing even illumination, low energy consumption, and long lifespan.
Ductwork Requirements Exhaust ducts must also be made of PVC or equivalent materials resistant to perchloric acid corrosion, with recommended washdown interface connections.
Optional Accessories Anti-splash faucet, dedicated wastewater collection tank, remote control system, airflow monitoring alarm, etc.
Applications
  • University Research Laboratories
  • Analytical Testing Centers
  • Industrial R&D Labs
  • Medical Institutions
Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
0%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

M
Modern Histopathology Grossing Station
Kazakhstan Jan 6.2026
This grossing station is really practical! The height-adjustable design allows us to flexibly adjust it to different working heights, making it comfortable for both standing and sitting operations, greatly reducing operator fatigue. The tabletop is sturdy and durable, and the material is easy to clean, making it perfect for frequent use in our laboratory. The overall design is well-thought-out, easy to operate, and simple to install. Highly recommended for laboratories or production environments that require an efficient and safe working platform!
C
Convenient And Safe Ordinary Pass Box For Cleanroom Material Transfer
Indonesia Jan 4.2026
The pass box performs reliably during material transfer in food cleanroom environments, effectively controlling contamination risks between areas of different cleanliness classes. Its easy-to-clean structure and food-grade materials comply with HACCP and GMP requirements, providing a reliable safeguard for food safety production.
L
Low Noise & Energy-Saving High-Efficiency Fan Filter Unit (FFU) for Cleanroom Applications
United States Dec 24.2025
We have used the FFU in our project, and the performance is excellent! It is energy-efficient, low-noise, and delivers uniform airflow, making it an essential unit for high-standard clean production lines.