logo
Cases
Home >

Guangzhou Cleanroom Construction Co., Ltd. company cases

Latest company case about Detailed Explanation of Color Steel Plate Column Cladding Detail Drawings: A Complete Guide from Materials to Construction

Detailed Explanation of Color Steel Plate Column Cladding Detail Drawings: A Complete Guide from Materials to Construction

Introduction In modern architectural decoration, color steel plate column cladding is widely used in public spaces such as shopping malls, office buildings, and airports due to its aesthetic appeal, durability, and ease of construction. This article provides a detailed analysis of the structural details of color steel plate column cladding, helping you fully understand the key aspects of this technique. Composition of Color Steel Plate Column Cladding 1. Aluminum Alloy Base Channel System The aluminum alloy base channel is the foundational support structure for color steel plate column cladding, typically installed around the column. Its features include: Made of high-strength aluminum alloy to ensure stability Precision groove design for easy insertion and fixation of color steel plates Corrosion-resistant treatment to extend service life 2. Perfect Coordination of Inside and Outside Corner Columns The key to color steel plate column cladding lies in the precise coordination of inside and outside corner columns: Aluminum Alloy Inside Corner Column: Used for internal corner connections Special design ensures tight seams Surface treatment matches the color steel plate for consistency Aluminum Alloy Outside Corner Column: Used for external corner edging Provides excellent edge protection Enhances overall structural strength Key Construction Techniques 1. Application of Sealant Sealant plays a crucial role in color steel plate column cladding: Fills gaps to prevent moisture penetration Provides expansion space to accommodate temperature changes Choose sealant colors that coordinate with the color steel plate for aesthetic consistency 2. Installation Process Measure and mark precise locations Install the aluminum alloy base channel, ensuring level and plumb alignment Cut and insert the color steel plates into the base channel Install the inside and outside corner columns Apply sealant to the seams Clean the surface and inspect quality Solutions to Common Issues 1. Gaps in Seams Check if the inside and outside corner columns are properly installed Ensure sufficient sealant filling Adjust the precision of color steel plate cutting 2. Surface Unevenness Inspect the flatness of the base channel installation Confirm that the color steel plates are not deformed Adjust the tightness of fasteners Maintenance and Care Recommendations Regularly inspect the condition of the sealant and repair as needed Use neutral cleaners for cleaning Avoid impacts from hard objects on the corner columns Conclusion The detail drawings of color steel plate column cladding showcase the intricate craftsmanship of modern architectural decoration. Through the coordinated use of aluminum alloy base channels, inside and outside corner columns, and sealant, not only is an aesthetically pleasing effect achieved, but long-term reliability is also ensured. Mastering these details will help you achieve better results in project implementation.  
2025-07-17
read more
Latest company case about Dye-Sealing Integrated Fume Hoods: Innovative Solution for Pathology Labs

Dye-Sealing Integrated Fume Hoods: Innovative Solution for Pathology Labs

Dye-Sealing Integrated Fume Hoods: Innovative Solution for Pathology Labs Combining Staining and Sealing Processes in a Safe Environment Introduction Dye-sealing integrated fume hoods represent a significant advancement in pathology laboratory equipment, combining tissue staining and sealing processes within a single, controlled environment. These specialized workstations provide both safety and efficiency for histopathology workflows while maintaining strict containment of hazardous chemicals. I. Working Principles of Dye-Sealing Integrated Fume Hoods   The dye-sealing fume hood operates on several innovative principles: 1. Dual-Process Integration: Combines tissue staining and slide sealing operations in one controlled workspace. 2. Zoned Containment: Features separate but connected areas for staining and sealing with independent airflow control. 3. Temperature Regulation: Maintains optimal conditions for both staining reactions and sealing processes. 4. Vapor Management: Specialized exhaust system handles both organic solvent vapors (from staining) and heated adhesive fumes (from sealing). 5. Cross-Contamination Prevention: Designed to prevent interference between staining chemicals and sealing materials.   II. Key Functions in Pathology Laboratories The dye-sealing integrated fume hood provides multiple critical functions: 1. Workflow Efficiency: Eliminates the need to transfer slides between separate staining and sealing stations. 2. Chemical Safety: Protects technicians from exposure to xylene, formaldehyde, and other hazardous staining reagents. 3. Process Control: Maintains consistent environmental conditions for both staining and sealing quality. 4. Specimen Protection: Reduces handling risks during the critical post-staining phase. 5. Regulatory Compliance: Helps meet OSHA, CLSI, and CAP standards for histopathology workflows.   III. Technical Specifications   Modern dye-sealing integrated fume hoods feature: - Divided work zones with adjustable partitions - Chemical-resistant stainless steel or epoxy resin construction - Independent temperature control for each zone - Programmable process timers - Built-in slide storage compartments - LED lighting with color rendering index >90 - Low-noise exhaust blowers (
2025-07-17
read more
Latest company case about The New Professional Choice: Comprehensive Analysis of the 1500*750*800 Negative Pressure Dissection Table

The New Professional Choice: Comprehensive Analysis of the 1500*750*800 Negative Pressure Dissection Table

In medical research, forensic autopsies, and pathological work, a fully functional and scientifically designed dissection table is key to improving efficiency and ensuring operational safety. Today, we will take an in-depth look at the 1500*750*800 negative pressure dissection table, which integrates multiple innovative designs to provide a comprehensive solution for professional dissection work. Core Features 1. Full Stainless Steel Antibacterial Structure Tabletop Panel: Made of SUS304 2.0mm thick stainless steel with special antibacterial treatment to effectively inhibit bacterial growth. Other Components: Constructed with SUS304 1.0mm stainless steel, ensuring a sturdy, durable, and easy-to-clean structure. 2. Innovative Negative Pressure Design Water-Air Separation Structure: Features an upward suction and downward exhaust system to effectively control harmful gases and splashes during dissection. Digital Pressure Difference Display: Monitors negative pressure in real-time to ensure a safe working environment. Detailed Functional Configuration Operating Area Design Adjustable Operating Panel: Can be repositioned as needed for enhanced flexibility. Three-Position IV Stand Holder: Accommodates infusion needs at different locations with user-friendly design. Professional Flushing System 8 Flushing Nozzles: Provide full coverage of the operating area for quick cleaning. Retractable Faucet: Adjustable positioning for various usage scenarios. Instant Hot/Cold Water Faucet: Delivers water at the desired temperature immediately, improving efficiency. Water Gun: High-pressure rinsing function for stubborn stains. Practical Functional Configurations Tissue Crusher & Switch: Integrated tissue processing for convenient operation. Spray Nozzle Switch: Controls the spray system for easy tabletop cleaning. Waterproof Socket: Safe power supply design for humid environments. Ventilation Louvers: Optimizes airflow for better exhaust efficiency. Control System Power & Fan Switches: Independent controls for easy operation. Digital Pressure Display: Real-time monitoring of environmental safety parameters. Summary of Advantages Hygiene & Safety: Full stainless steel antibacterial material + negative pressure design minimizes cross-contamination risks. Comprehensive Functionality: Combines dissection, flushing, and crushing functions to meet professional needs. Ergonomic Design: Adjustable components and multifunctional configurations enhance user comfort. Easy Maintenance: Stainless steel material and well-designed structure simplify cleaning and disinfection. This 1500*750*800 negative pressure dissection table is particularly suitable for hospital pathology departments, forensic labs, medical schools, and other settings requiring high-standard dissection environments. Its comprehensive features and reliable design will significantly improve dissection efficiency and quality while providing a safer and more comfortable workspace for operators. For institutions seeking professional-grade dissection equipment, this negative pressure dissection table—combining practicality and innovation—is undoubtedly a worthy consideration.  
2025-07-16
read more
Latest company case about Analysis of Corner Detail Design in Clean Areas of the Semiconductor and Electronics Industry

Analysis of Corner Detail Design in Clean Areas of the Semiconductor and Electronics Industry

In the design of cleanrooms for the semiconductor and electronics industry, corner treatment is a seemingly simple yet critically important detail. Today, I will provide a detailed analysis of a common corner detail design for clean areas, which adopts a combined structure of aluminum alloy and color steel plates, balancing aesthetics, durability, and cleanliness requirements. Key Components of the Corner Detail Schematic 1. Aluminum Alloy Outer Corner R50 Function: Serves as the external protective layer and decorative surface of the corner. Specifications: Designed with a 50mm radius arc (R50). Advantages: Arc design prevents dust accumulation and facilitates cleaning. Aluminum alloy material is corrosion-resistant and oxidation-resistant. Smooth surface does not generate dust, meeting cleanliness requirements. Arc transition reduces airflow vortices, maintaining laminar flow. 2. 50mm Thick Color Steel Plate Core Structure: Acts as the main wall material. Characteristics: 50mm thickness provides sufficient structural strength. Sandwich panel structure offers excellent thermal insulation. Surface coating is anti-static and corrosion-resistant. Complies with cleanroom requirements for non-dust-generating and non-dust-accumulating surfaces. 3. Rivet Fixation Connection Method: Secures the aluminum alloy corner to the color steel plate. Advantages: Quick and easy installation, suitable for rapid cleanroom construction. Firm and reliable connection with no risk of loosening. No welding required, avoiding the generation of contaminating particles. Smooth surface with no protruding elements. 4. Aluminum Alloy Inner Arc R50 Internal Treatment: Symmetrical arc design matching the outer corner. Functions: Forms a complete arc transition with no dead corners. Facilitates cleaning and disinfection, preventing microbial growth. Maintains smooth internal airflow. Enhances overall aesthetics and professionalism. Design Key Points Analysis Cleanliness Considerations: Double-arc design completely eliminates 90-degree sharp corners, preventing dust accumulation. All material surfaces are smooth and non-porous, meeting Class 100-10,000 cleanliness requirements. Minimized seams reduce contamination risks. Structural Stability: 50mm thick color steel plates provide sufficient wall strength. Rivet spacing is typically controlled at 150-200mm to ensure firm connections. Aluminum alloy edging enhances corner impact resistance. Installation Process: Install color steel plate walls first, leaving space for corners. Customize aluminum alloy corner pieces after precise measurements.
2025-07-16
read more
Latest company case about Proper Placement and Environmental Requirements for Negative Pressure Dissection Tables: Ensuring Safety and Efficient Operation

Proper Placement and Environmental Requirements for Negative Pressure Dissection Tables: Ensuring Safety and Efficient Operation

In laboratories, forensic institutions, or medical facilities, negative pressure dissection tables are essential equipment for pathological examinations and autopsies. Their correct installation not only affects the lifespan of the equipment but also directly impacts the safety of operators and the accuracy of experimental results. This article details the placement and environmental requirements for negative pressure dissection tables to help you optimize equipment setup and ensure long-term stable operation. 1. Environmental Requirements for Negative Pressure Dissection Tables The working environment of a negative pressure dissection table significantly influences its performance. The following are key environmental parameters: Environmental Factor Standard Requirement Consequences of Non-Compliance Ambient Temperature Above 10°C (50°F) Low temperatures may cause condensation or operational issues Relative Humidity Below 60% High humidity can lead to electrical shorts or metal corrosion Ambient Airflow Less than 0.2 m/s Strong airflow may disrupt negative pressure efficiency Radiant Heat No direct heat sources High temperatures accelerate material degradation Key Points Explained Temperature Control: Below 10°C, condensation may form inside the device, posing electrical risks. Humidity Management: Excess moisture can corrode circuits or promote microbial growth; a dehumidifier is recommended. Stable Airflow: Avoid strong drafts (e.g., fans, ventilation systems) to maintain consistent negative pressure. 2. Placement Guidelines for Negative Pressure Dissection Tables (1) Level and Stable Surface Must be placed on a flat, sturdy surface to prevent tilting, which can deform the equipment or compromise door seals. If the surface is uneven, use adjustable leveling feet or anti-vibration pads. (2) Avoid Damp or Leak-Prone Areas Keep away from water pipes, basements, or bathrooms to prevent moisture ingress. Damp environments may cause: Electrical shorts Rust on metal components Microbial growth, compromising hygiene (3) Shield from Direct Sunlight and Heat Sources Avoid placement near windows or under direct sunlight, as UV rays degrade exhaust tubing and seals. Maintain at least 1.5 meters (5 feet) from heat-emitting devices (e.g., ovens, heaters). (4) Keep Clear of HVAC Vents Stay ≥3 meters (10 feet) from air conditioner vents to prevent: Condensation due to temperature fluctuations Airflow interference with negative pressure stability (5) Dedicated Power Supply with Safety Measures Use an independent circuit—avoid sharing with high-power devices (e.g., centrifuges, refrigerators). Ensure proper grounding (ground resistance ≤4Ω) to prevent static or leakage currents. Install a residual-current device (RCD) and test it regularly. 3. Additional Optimization Tips Beyond basic requirements, these measures enhance performance and safety: Allow ≥30 cm (12 inches) clearance around the table for ventilation. Inspect exhaust tubing periodically for kinks or blockages. In high-vibration areas (e.g., near heavy machinery), use anti-vibration mounts. Quarterly checks of environmental conditions (temperature, humidity, power stability). 4. Conclusion: Keys to Safe Operation Proper installation of negative pressure dissection tables ensures both equipment longevity and user safety. Adhere to these principles: Stable Environment: Control temperature, humidity, and airflow. Optimal Placement: Avoid moisture, sunlight, and HVAC vents. Electrical Safety: Independent circuit + grounding + RCD protection. With careful setup and maintenance, negative pressure dissection tables can deliver reliable performance for pathology, forensics, and research. For specialized installations (e.g., high-humidity or high-vibration environments), consult a professional for customized solutions!  
2025-07-16
read more
Latest company case about High-Efficiency Air Supply Outlet Solution: Key Design for Optimizing Airflow

High-Efficiency Air Supply Outlet Solution: Key Design for Optimizing Airflow

In modern cleanrooms, laboratories, and medical environments, efficient air distribution systems are critical for maintaining cleanliness and comfort. This article details a high-efficiency air supply outlet solution with dimensions of 332×330×420mm and a rated airflow of 500 CMH, designed specifically for applications requiring precise air control. Core Product Specifications Dimensions: 332mm (W) × 330mm (D) × 420mm (H) Rated Airflow: 500 cubic meters per hour (CMH) Matching HEPA Filter: 320×320×90mm Damper Configuration: Manual regulating damper Flange Connection: 200×200mm standard size Material and Structural Features This high-efficiency air supply outlet is constructed entirely from cold-rolled steel plates, ensuring durability and long-term stability. Cold-rolled steel offers excellent strength and corrosion resistance, making it particularly suitable for cleanroom environments. The compact structural design integrates the air outlet, filter, and damper into a single unit, saving installation space while ensuring efficient system operation. The 420mm height provides sufficient plenum space for uniform downward airflow distribution. HEPA Filter Configuration The matching 320×320×90mm HEPA filter is the core component of this solution: H13/H14-grade filter media, achieving 99.97%-99.99% filtration efficiency for 0.3μm particles The 90mm thickness balances filtration efficiency and pressure drop Standard size facilitates easy replacement and maintenance Sealed connection with the air outlet body prevents bypass leakage Airflow Regulation System The product is equipped with a manual regulating damper, providing flexible airflow control: Allows precise adjustment of supply airflow based on zone requirements Damper structure ensures linear airflow adjustment characteristics Simple and intuitive operation, requiring no special tools Locking mechanism secures the set airflow to prevent accidental changes The 200×200mm standard flange connection enables easy integration with existing duct systems, significantly simplifying installation. Recommended Applications This high-efficiency air supply outlet is ideal for: Hospital operating rooms and ICU wards Biosafety laboratories Cleanrooms in the electronics industry GMP facilities in the pharmaceutical industry Sterile packaging areas in the food industry Installation and Maintenance Recommendations Inspect filter integrity before installation Ensure proper sealing at flange connections Gradually adjust airflow to design values during initial commissioning Check filter pressure drop every 6-12 months Replace the filter when final resistance reaches twice the initial value Summary of Technical Advantages Precise air distribution: Uniform airflow with no dead zones High-efficiency filtration: Ensures clean air supply Flexible airflow adjustment: Adapts to varying operational needs Compact structural design: Saves installation space Reliable material selection: Guarantees long-term stable performance With its refined design and dependable performance, this 332×330×420mm high-efficiency air supply outlet solution is an ideal choice for air handling systems in various clean environments. Whether for new construction or retrofit projects, it delivers efficient and stable air distribution, creating compliant clean environments for users.  
2025-07-16
read more
Latest company case about Negative Pressure Dissection Table: The Guardian of Safety in Pathology Laboratories

Negative Pressure Dissection Table: The Guardian of Safety in Pathology Laboratories

In the daily operations of pathology laboratories, harmful gases generated during dissection have always been a significant threat to the health of staff. Particularly, toxic substances such as formaldehyde released during the process can cause serious health issues with prolonged exposure. The emergence of negative pressure dissection tables has provided an ideal solution to this challenge. Core Product Features Through precise engineering design, the negative pressure dissection table achieves a negative pressure state on its surface. This innovative design effectively captures and exhausts all harmful gases produced during dissection. Unlike traditional ventilation equipment, the negative pressure dissection table offers the following outstanding advantages: Comprehensive Gas Capture: Utilizes inward-sloping suction vents on both sides and perforated suction openings beneath the dissection table to ensure no harmful gases escape. Clean and Safe Environment: A well-designed ventilation system thoroughly eliminates the retention of harmful gases like formaldehyde, creating a safe workspace for laboratory personnel. Ergonomic Design: The human-centric design takes into account the practical needs of operators, making dissection procedures more convenient and efficient. Customizable Configurations: Offers various models and optional accessories to meet the specific requirements of different laboratories. Superior Working Principle The core of the negative pressure dissection table lies in its innovative negative pressure exhaust system. During operation, the system establishes a stable negative pressure environment in the dissection area, effectively isolating the workspace from the surrounding environment. This design ensures: All harmful gases are immediately captured and exhausted, preventing diffusion within the laboratory. Staff remain in a clean air environment, minimizing health risks. The system operates with low noise and moderate airflow, fully complying with human comfort standards. Compliance with Highest Safety Standards Our negative pressure dissection tables strictly adhere to all requirements of the "China Safety and Environmental Protection Regulations", achieving industry-leading levels in space utilization, noise control, and airflow design. The equipment is not only fully functional but also user-friendly and reliable, having been validated by numerous pathology laboratories. Safeguarding Health In pathology laboratories, safety is always the top priority. The negative pressure dissection table is more than just a piece of laboratory equipment—it is a solemn commitment to the health of staff. It represents the latest standard in laboratory safety protection and is an indispensable asset for modern pathology laboratories. Whether you are setting up a new pathology laboratory or upgrading existing equipment, the negative pressure dissection table is the most worthwhile choice. We offer a variety of configuration options tailored to your specific needs, helping you create the safest and most efficient working environment for your laboratory.  
2025-07-15
read more
Latest company case about High-Efficiency Class 10,000 Air Supply Ceiling: In-Depth Analysis of the 2600*1400*500mm Product

High-Efficiency Class 10,000 Air Supply Ceiling: In-Depth Analysis of the 2600*1400*500mm Product

2025-07-14
read more
Latest company case about Comprehensive Guide to Laboratory Drying and Heat Treatment Equipment: 6 Professional Devices Explained

Comprehensive Guide to Laboratory Drying and Heat Treatment Equipment: 6 Professional Devices Explained

In modern laboratories, selecting the right equipment is crucial for smooth scientific research. Today, I will provide a detailed introduction to several common laboratory devices to help you understand their features and advantages. 1. Central Laboratory Bench This all-steel floor-standing workbench is the core workspace in a lab, featuring: Work Surface: A 15mm thick black ceramic top, made from high-temperature-fired solid ceramic specifically designed for laboratory use, offering excellent corrosion resistance, heat resistance, and impact resistance. Hardware: Equipped with DTC damping hinges and three-section silent slides, ensuring smooth and quiet drawer operation while extending service life. Structural Stability: The all-steel construction provides outstanding load-bearing capacity and durability. 2. Laboratory Side Platform As an auxiliary workspace, the side platform also adopts high-standard configurations: Frame Structure: All-steel floor-standing frame ensures stability. Work Surface: The same 15mm thick black ceramic top as the central bench, maintaining workspace consistency. Detail Design: DTC buffered hinges and three-section silent rails enhance user experience. 3. Fume Hood Essential for handling hazardous gases, the fume hood offers: Ventilation Capacity: Adjustable exhaust volume of 450-1600 m³/h to accommodate different experimental needs. Safety Parameters: Work surface wind speed of 0.3-0.8 m/s ensures effective capture of harmful gases. Operational Convenience: A 650-700mm glass door height provides good visibility and workspace. Electrical Configuration: Standard operating voltage of AC220V/10A. 4. Laminar Flow Hood A solution for experiments requiring a clean environment: Cleanliness Class: Achieves ISO14644-1 Class 100 cleanliness. Airflow Control: Rated airflow of 1200-2300 m³/h with an average wind speed of 0.3-0.6 m/s. Filtration Performance: 99.99% filtration efficiency for 0.3μm particles. 5. Biological Safety Cabinet A critical protective device for handling biological samples: Airflow System: Downflow at 0.33 m/s and inflow at 0.53 m/s for dual protection. Exhaust Capacity: Total system exhaust volume of 1050-1270 m³/h. Disinfection Setup: 30W-40W UV lamp provides additional sterilization. Filtration Efficiency: 99.995% filtration efficiency for 0.3μm particles, far exceeding standard clean equipment. How to Choose the Right Laboratory Equipment When selecting lab equipment, consider the following factors: Experiment Type: Chemical experiments prioritize fume hoods, while biological experiments require biosafety cabinets. Space Layout: A balanced combination of central workbenches and side platforms. Safety Requirements: Choose equipment with appropriate protection levels based on hazard classification. Budget Considerations: Balance initial investment with long-term usage costs. High-quality laboratory equipment not only improves efficiency but also provides researchers with a safe and reliable working environment. We hope this article helps you better understand the key points in selecting lab equipment.    
2025-07-11
read more
Latest company case about What is the Purpose of Laminar Flow?

What is the Purpose of Laminar Flow?

Laminar flow is a fundamental concept in fluid dynamics and engineering, designed to maintain smooth, predictable, and contamination-free airflow. Its primary purpose is to minimize turbulence, ensuring that air or liquid moves in parallel layers without mixing. This makes it essential in industries where precision, sterility, and particle control are critical. Why Is Laminar Flow Important? 1. Prevents Contamination In medical labs, hospitals, and pharmaceutical facilities, laminar flow systems (such as laminar airflow hoods) prevent airborne microbes, dust, and particles from contaminating sensitive samples, surgical sites, or sterile drugs. Example: Operating rooms use laminar airflow to reduce infection risks during surgeries. 2. Enhances Manufacturing Precision In semiconductor and electronics manufacturing, even microscopic dust particles can ruin microchips. Laminar flow ensures a cleanroom environment where air is continuously filtered. Example: Microchip fabrication requires ISO Class 1-5 cleanrooms with strict laminar airflow control. 3. Improves Product Quality in Food & Pharma Food processing plants and pharmaceutical companies use laminar flow to maintain hygiene, preventing bacteria or particulates from compromising product safety. Example: Vaccine production relies on laminar flow to avoid contamination. 4. Supports Scientific Research Laboratories handling cell cultures, nanotechnology, or chemical experiments depend on laminar flow to prevent cross-contamination. Example: Biosafety cabinets use laminar airflow to protect researchers and samples. How Does Laminar Flow Work? Laminar flow systems use HEPA/ULPA filters to purify air and direct it in a straight, unidirectional path. There are two main types: Vertical Laminar Flow Air moves downward (common in cleanrooms and surgical suites). Horizontal Laminar Flow Air moves horizontally (used in lab workbenches). The airflow speed is typically 0.3–0.5 m/s, ensuring particles are carried away without turbulence. Key Benefits of Laminar Flow ✔ Eliminates Airborne Contaminants – HEPA filters remove 99.97% of particles.✔ Reduces Infection Risks – Critical in hospitals and labs.✔ Increases Process Reliability – Essential for high-tech manufacturing.✔ Energy Efficient – Optimized airflow reduces energy waste. Conclusion Laminar flow is a cornerstone of modern sterile environments, ensuring safety and precision in healthcare, manufacturing, and research. Whether in a hospital, lab, or factory, controlling airflow direction and purity is vital for success. Need help selecting a laminar flow system? Let me know your requirements, and I’ll guide you to the best solution!
2025-07-23
view more
Latest company case about What is Ceiling Suspended LAF Used For?

What is Ceiling Suspended LAF Used For?

Introduction In modern cleanrooms, laboratories, and medical environments, ceiling-mounted laminar air flow (LAF) units are highly efficient airflow control devices. By providing unidirectional, vertically downward clean airflow, they create a highly sterile environment for critical work areas. This article will delve into the core applications, working principles, suitable scenarios, and unique advantages of ceiling-mounted LAF units compared to traditional laminar flow equipment. 1. What Is a Ceiling-Mounted Laminar Air Flow Unit? A ceiling-mounted LAF unit is a clean air delivery system fixed to the ceiling, typically composed of HEPA/ULPA filters, a fan, and airflow guidance components. Its core functions include: Generating vertical unidirectional laminar airflow Continuously filtering airborne particles (e.g., microorganisms, dust) Protecting the workspace below from contamination 2. Key Applications 1. Medical and Operating Rooms Sterile surgical field coverage: Provides an ISO Class 5 (Class 100) clean environment for high-risk surgeries such as orthopedics and burn treatments. ICU or transplant wards: Protects immunocompromised patients from airborne infections. 2. Pharmaceutical and Biological Laboratories Aseptic compounding and filling: Used for preparing high-risk formulations like vaccines and injectables. Cell culture and genetic manipulation: Prevents cross-contamination of samples. 3. Electronics Manufacturing Precision component assembly: Prevents microdust from affecting sensitive components like chips and optical lenses. 4. Food Industry Aseptic packaging zones: Extends the shelf life of perishable foods (e.g., dairy products, prepared meals). 3. Working Principle Air intake: The fan draws air from the room or external environment. High-efficiency filtration: HEPA/ULPA filters remove particles ≥0.3μm (with ≥99.99% efficiency). Laminar airflow output: Clean air flows vertically downward at a constant speed of 0.3–0.5 m/s, forming an "air curtain" barrier. Contaminant removal: Airflow carries particles away from the work area, expelling them through bottom or side return systems. 4. Advantages Over Traditional LAF Units Feature Ceiling-Mounted LAF Traditional Benchtop/Standalone LAF Space efficiency No floor space required Requires dedicated bench or stand Coverage area Large, uniform protection (e.g., surgical tables) Limited to small work areas Airflow control Vertical unidirectional, more stable Horizontal/vertical, prone to disruption Suitable scenarios Dynamic multi-person environments Static single-person operations 5. Selection and Maintenance Tips 1. Key Purchasing Considerations Filter grade: H14 HEPA or U15 ULPA for medical/pharmaceutical applications. Noise and airflow speed: ≤55 dB for operating rooms, adjustable speed (0.3–0.5 m/s). Material: Stainless steel frames for corrosion resistance in cleanrooms. 2. Routine Maintenance Monthly checks: Filter pressure differential (replace if twice the initial value). Annual certification: ISO 14644-1 cleanliness testing. Avoid UV light: Prevents damage to filter fibers. Conclusion Ceiling-mounted LAF units, with their high-efficiency filtration + vertical laminar airflow design, serve as "invisible guardians" in high-demand fields like healthcare and pharmaceuticals. Their space-saving and wide-area protection features make them indispensable in modern facilities. Does your industry need such equipment? Feel free to discuss in the comments! Follow us for more cleanroom technology insights!
2025-07-22
view more
Latest company case about In-Depth Analysis and Construction Guidelines for the Return Air Column System in Class 100 Cleanrooms

In-Depth Analysis and Construction Guidelines for the Return Air Column System in Class 100 Cleanrooms

2025-07-22
view more
Latest company case about Analysis and Construction Key Points of Wall-Ceiling Connection Details for Class 100 Cleanrooms

Analysis and Construction Key Points of Wall-Ceiling Connection Details for Class 100 Cleanrooms

Introduction In the design and construction of Class 100 cleanrooms, the connection between walls and ceilings is one of the critical nodes to ensure cleanliness standards are met. Today, I will provide a detailed analysis of a typical wall-ceiling connection detail for Class 100 cleanrooms, focusing on its structural composition, material selection, and key construction points. Detailed Analysis of the Connection Detail 1. Main Components This connection detail primarily consists of the following key components: Soft Polyurethane Sponge: Acts as a cushioning and sealing material at the joint. Aluminum Allogy Corner Column: Forms the skeleton structure of the connection. Aluminum Alloy Base Channel: Provides fixing and support. Sealant: Ensures the final air-tightness. 2. Layered Construction Breakdown 2.1 Base Treatment First, embedded parts or mounting bases are installed at the top of the wall to ensure sufficient load-bearing capacity for the entire ceiling system. The base surface must be flat, dust-free, and free of oil stains to ensure proper adhesion of subsequent materials. 2.2 Installation of Aluminum Alloy Base Channel The aluminum alloy base channel is fixed to the top of the wall using stainless steel bolts or specialized connectors. Key installation considerations include: Level tolerance controlled within ±1mm/m. Tight alignment at joints, with gaps not exceeding 0.5mm. Fixing point spacing should not exceed 600mm. 2.3 Soft Polyurethane Sponge Installation Soft polyurethane sponge is laid over the aluminum alloy base channel, serving the following functions: Cushioning vibration transmission. Aiding in sealing. Compensating for structural deformation. The sponge should be installed continuously, with joints cut at an angle and sealed using specialized tape. 2.4 Installation of Aluminum Alloy Corner Column The aluminum alloy corner column is a key transition component connecting the wall and ceiling, featuring: Specialized cleanroom profiles with anodized surfaces. Internal radius compliant with cleanroom non-accumulation requirements. Snap-fit connection with the base channel for easy disassembly and maintenance. Special attention must be paid to the joint treatment between the corner column, wall panels, and ceiling panels. 2.5 Sealant Application Finally, neutral silicone sealant is applied to all joints to form a complete airtight barrier. Key points for sealant application: Surfaces must be cleaned before application to ensure they are dust-free and oil-free. Sealant width should ideally be 6-10mm. Specialized tools should be used to shape the sealant into a concave arc. Maintain a clean environment during curing. Material Selection Criteria 1. Soft Polyurethane Sponge Density: ≥25kg/m³. Resilience: ≥60%. Fire rating: At least B1 grade. Aging resistance: No significant deformation after 168 hours at 100°C. 2. Aluminum Alloy Profiles Material: 6063-T5 or higher grade. Surface treatment: Anodized coating thickness ≥15μm. Dimensional tolerance: ±0.2mm. Straightness: ≤0.3mm/m. 3. Sealant Type: Neutral-cure silicone sealant. Movement capability: ≥25%. VOC content: ≤50g/L. Mold resistance rating: Grade 0. Key Quality Control Points for Construction Dimensional Control: All joint gaps should be uniform, with cumulative error not exceeding 2mm. Clean Construction: Maintain positive pressure in the work area. Use dust-free tools. Clean as you work. Air-Tightness Testing: Conduct pressure decay testing. Leakage rate ≤0.1%/h at 1000Pa pressure difference. Surface Treatment: No visible scratches or dents. Uniform color and finish. Smooth joints without abrupt changes. Common Issues and Solutions Issue 1: Dust Accumulation in Corners Cause: Insufficient internal radius or rough surfaces. Solution: Use corner columns with R≥30mm and surface roughness Ra≤0.8μm. Issue 2: Joint Cracking Cause: Mismatched thermal expansion coefficients or insufficient sealant movement capability. Solution: Use high-elasticity sealant and leave appropriate expansion gaps. Issue 3: Vibration Transmission Cause: Insufficient compression of the polyurethane sponge. Solution: Increase sponge thickness or density to ensure 15-20% compression. Conclusion The connection between walls and ceilings in a Class 100 cleanroom may appear simple, but it involves multiple precision designs and strict construction requirements. Only through proper material selection, precise structural treatment, and rigorous construction control can this critical junction maintain long-term sealing performance and cleanliness assurance. I hope this article proves useful to professionals involved in cleanroom design and construction, and I welcome further discussion on practical experiences.  
2025-07-21
view more
Latest company case about What is the Difference between Laminar Flow and Fan Filter Unit?

What is the Difference between Laminar Flow and Fan Filter Unit?

When setting up a cleanroom or controlled environment, two common solutions for maintaining air purity are Laminar Flow Systems and Fan Filter Units (FFUs). While both are designed to provide clean air, they serve different purposes and operate in distinct ways. In this blog, we’ll explore the differences between laminar flow and FFUs, their working principles, and their best-use cases. 1. What is Laminar Flow? Laminar flow refers to the smooth, unidirectional movement of air at a constant velocity, minimizing turbulence and particle contamination. It is commonly used in environments requiring high cleanliness, such as laboratories, pharmaceutical production, and electronics manufacturing. Key Features of Laminar Flow Systems: Unidirectional airflow (vertical or horizontal) HEPA or ULPA filters to remove particles Constant air velocity (typically 0.3–0.5 m/s) Used in clean benches, biosafety cabinets, and cleanroom ceilings Laminar flow systems ensure that contaminants are swept away from critical work areas, making them ideal for processes requiring sterile conditions. 2. What is a Fan Filter Unit (FFU)? A Fan Filter Unit (FFU) is a modular air filtration device that combines a fan and a HEPA/ULPA filter to recirculate and purify air. FFUs are often used in cleanrooms, semiconductor manufacturing, and other controlled environments. Key Features of FFUs: Self-contained unit with a fan and filter Modular design (can be installed in grids) Variable airflow control (adjustable speed) Energy-efficient compared to full HVAC laminar flow systems FFUs are typically installed in ceilings or walls to maintain air cleanliness in large cleanrooms without requiring a full laminar flow setup. 3. Key Differences Between Laminar Flow and FFUs Feature Laminar Flow System Fan Filter Unit (FFU) Airflow Type Unidirectional (laminar) Recirculated, not always laminar Design Fixed installation (clean benches, hoods) Modular, can be added in multiples Air Velocity Constant, controlled Adjustable via fan speed Application Small, critical work zones Large cleanroom environments Energy Use Higher (full HVAC support) Lower (individual units) Cost Higher initial setup More cost-effective for large areas 4. Which One Should You Choose? Choose Laminar Flow If: ✔ You need sterile, particle-free workspaces (e.g., labs, medical device manufacturing). ✔ You require consistent unidirectional airflow. ✔ Your application involves smaller, critical zones. Choose FFUs If: ✔ You need scalable air filtration for large cleanrooms. ✔ You want energy-efficient, modular units. ✔ Your facility requires flexible airflow control. 5. Conclusion Both laminar flow systems and Fan Filter Units (FFUs) play crucial roles in contamination control, but they serve different needs. Laminar flow is best for precision environments requiring ultra-clean conditions, while FFUs offer a flexible, cost-effective solution for large-scale cleanrooms. Understanding these differences will help you select the right system for your specific air cleanliness requirements.  
2025-07-21
view more
1 2 3 4 5 6 7 8
1 2 3 4